CYBER RESILIENCE ACT

CRA cybersecurity risk assessment: a worked IoT example

Follow a fictional T100 temperature sensor from its product boundary to risk criteria, controls, evidence and a release decision under the Cyber Resilience Act.

1. Define intended use and the product boundary

T100 measures warehouse temperatures. The baseline is hardware A, firmware 1.4.0, app 2.3 and the manufacturer's service API v2. Local readings work offline; remote alerts require the service, so the example includes it in the assessment. T100 is not a life-safety alarm. Foreseeable conditions include internet outages and shared operator devices.

2. Define criteria before rating the risks

For this example, disclosing a customer's data or silently losing an alert is high impact. A reversible interruption with a visible warning is medium impact. Assess likelihood qualitatively from exposure, operating conditions and test results. High impact without a verified control blocks release in this example. This is a team rule, not a threshold set by the CRA.

3. Record the risk, control and test

Worked T100 scenarios with fictional results
RiskControlEvidence and state
R-01 · Readings visible to another customerService-side authorisation and isolation of customer data.Two controlled accounts and both roles: verify access is refused in API v2. Illustrative result: pass; residual risk awaits acceptance.
R-02 · Interrupted update leaves the sensor unusableSignature verification and recovery to the previous working version.Verify rejection of an invalid package and recovery after power loss. Illustrative result: pass on hardware A.
R-03 · Network outage interrupts remote alarmsVisible offline status and verified reconnection.Full outage–recovery test is missing. Residual risk not established; QA owns the test before the release decision.

4. Record the decision and reassessment triggers

Example R-01 record: high impact and possible occurrence before the control; after the test, impact remains high but occurrence is assessed as less likely within the tested scope. This is not automatic acceptance. R-03 lacks evidence for lowering the rating: hold release pending verification.

Article 13(3)–(4) connects the assessment to lifecycle activities and the technical file. Reassess when remote functionality or update architecture changes, or when material vulnerability information emerges.

Primary source: Cyber Resilience Act

Continue with the T100 example

Explore CRA Workspace →